Why LTO?

D-Cell Management System (BMS)

Specifications

Performance & Safety

Applications

About

Login

D-Cell LTO80Ah specifications

Below you'll find a concise overview of the D-CellLTO80Ah's key parameters. We start with a plainlanguage summary and then provide detailed tables for engineers and system integrators.

Summary

  • Energy & capacity:  Each module stores around 1 kWh of energy with a nominal capacity of 80Ah
  • Voltage:  13.5V nominal (2P6S configuration) with an operating range between 12V and 15V
  • Current handling:  160A continuous charge/discharge and peaks up to 1300A for <0.3s
  • Efficiency:  98% at 0.25C reference
  • Cycle life:  ≥30 000 cycles at 80% depth of discharge
  • Operating environment: Functionality maintained from -40°C to +65°C without active cooling

Electrical characteristics

Key electrical parameters
ParameterValueNotes
Nominal voltage13.5V2P6S LTO configuration
Nominal capacity80Ah1kWh energy per module
Operating voltage range12 - 15VControlled by the BMS
Optimal charge current20A (0.25°C)Recommended for routine charging
Maximum charge current160A continuous; 500A peak <1.8sAcross -40 - +65°C
Maximum discharge current160A continuous; 1300A peak <0.3sAcross -40 - +65°C
Internal resistance<3.5mΩ (pack)≤1mΩ per cell at 25°C
Efficiency98%Measured at 0.25C
Cycle life≥30 000 cyclesAt 80% depth of discharge, 20°C
Self-discharge<0.1% per monthNegligible self-discharge in sleep mode
ParameterValueNotes

Mechanical & environmental characteristics

Key mechanical and environmental parameters
ParameterValueNotes
Dimensions (L x W x H)406 x 140 x 230mmCompact footprint
Mass17.5kg ±3%Lightweight for its class
Housing materialFiberglass-reinforced polycarbonateHigh impact resistance
TerminalsBrass M8 posts20Nm maximum torque with 10 mm thread engagement
Installation orientationAny (stackable)Can be installed horizontally or vertically
Ingress protectionIP67 (optional IP69)Immersion-proof; optional high-pressure jet protection
Operating temperature-40°C to +65°CNo active cooling required
Storage (≤1 month)-20°C to +45°CMax. 95% relative humidity
Storage (≤1 year)-20°C to +25°CMax. 95% relative humidity
Altitude limitUp to 15 000mTested per UN 38.3 T.1
Vibration resistance1 Gn/0.8mm/2Gn; 7-200HzTested on 3 axes for 9 hours
Shock resistance40.6Gn, 11ms18 half-sine shocks
Noise level<25dB(A) at 1mSilent operation
Mean time between failures≥1 000 000 hoursHigh reliability
Cycle life (environmental tests)≥30 000 cyclesMeasured at 20A (0.25C)
ParameterValueNotes